IS 3589 : 2001
Steel pipes for water and sewage (168.3 To 2540 Mm Outside Diameter) - Specification (Third Revision)
Current edition: 2001
BIS department: MTD
What this standard covers
This standard applies to seamless and welded carbon steel pipes for water and sewage of outside diameter from 168.3 to 2 540 mm.
Scope, quoted from IS 3589 : 2001. Read the full standard
Requirements and tests, as the standard names them
- 3.2 Hydrostatic Test Pressure
- 9.2 Flattening or Bend Test
- 5.2.2 Bend Test/or ERW Pipes
- 9.2.3 Flattening Test for Seamless Pipes
Sub-clause names whose printed names themselves say “Test” in IS 3589 : 2001. Values and limits are deliberately not reproduced here — read them in the standard itself.
How the standard is organised
- 4 INFORMATION TO BE SUPPLIED BY THE PURCHASER WHILE PLACING ORDER
- 5 DESIGNATION
- 6 QUALITY OFSTEEL
- 7 MANUFACTUREOFTHE PRODUCT
- 9 MECHANICALPROPERTIES
- 10 HYDRAUUCPRESSURETEST
- 11 DIMENSIONS AND MASS PER METRE RUN
- 13 NUMBER, SELECTION AND PREPARATION
- 14 VISUAL INSPECTION, APPEARANCE AND WORKMANSHIP
- 15 CONDITION OF SUPPLY
- 17 JOINTS AND ENDS
Edition history (per the BIS registry)
- IS 3589 : 2001 — current edition
Where this standard is used on NirmanDost
CPWD DSR E&M 2022
| Item code | Description (verbatim) |
|---|---|
| 16.1.1 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges… |
| 16.1.2 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges… |
| 16.1.3 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges… |
| 16.1.4 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges… |
| 16.1.5 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges… |
| 16.1.6 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges… |
Pick up from here
CivicMateSearch 4,300+ CPWD DSR and municipal SOR items, then build a priced BOQ.Open CivicMate →
Nirman AI on WhatsAppMessage NirmanDost on WhatsApp — the same AI answers you there. No app, no sign-up.Ask on WhatsApp →
Get listed on NirmanDostCreate a free account, list your business and showcase your work — customers find you here.Create free account →
Notes
- Status and titles come from the official BIS published/withdrawn standards registry (standards.bis.gov.in exports, July 2026 snapshot). Editions change — verify on the BIS portal before contractual use.
- The standard text is copyright BIS. NirmanDost shows registry metadata and links to the official source only — it never rehosts the document.
- Generated 2026-07-27.