What this standard covers

This standard applies to manually operated general-purpose switches for alternating currents only, with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and similar fixed-electrical installations either indoors or outdoors. 1.2 The rated current is limited to 16 A for switches provided with screw less terminals.

Scope, quoted from IS 3854 : 2023. Read the full standard

Requirements and tests, as the standard names them

  • 13.2 Installation Requirements
  • 13.4 Openings in Normal Use
  • 13.6 Mounting Means
  • 13.7 Combinations of Switches
  • 13.8 Accessories Combined with Switches
  • 13.9 Surface-type Switches Having an IP Code
  • 13.10 Installation in a Box
  • 13.11 Connection of a Second Current-carrying
  • 13.12 Inlet Openings
  • 13.15 Requirements for Membranes in Inlet
  • 13.16 Pilot Light Units
  • 16.2 Test for Measuring the Insulation Resistance
  • 16.3 Electric Strength Test
  • 18.3 Overload Test with Filament Lamps
  • 19.2 Test for Switches Intended for Externally
  • 19.3 Test for Switches Intended for Self-ballasted
  • 20.2 Pendulum Hammer Test
  • 20.10 Additional Test for Cord-operated Switch
  • 21.2 Basic Heating Test
  • 26.1 Type Tests
  • 26.2 Acceptance Tests
  • 26.3 Routine Tests

Sub-clause names as printed under the headings “CONSTRUCTIONAL REQUIREMENTS”, “TESTS”, and those whose printed names themselves say “Test” in IS 3854 : 2023. Values and limits are deliberately not reproduced here — read them in the standard itself.

How the standard is organised

  • 4 GENERAL REQUIREMENTS
  • 5 GENERAL NOTES ON TESTS
  • 6 RATINGS
  • 7 CLASSIFICATIONS
  • 9 CHECKING OF DIMENSIONS
  • 10 PROTECTION AGAINST ELECTRIC
  • 11 PROVISION FOR EARTHING
  • 12 TERMINALS
  • 12 APRINCIPLE OF THE TEST APPARATUS FOR DEFLECTION ON SCREWLESS TERMINALS
  • 12 B EXAMPLE OF TEST ARRANGEMENT TO MEASURE THE VOLTAGTE DROP DURING TEST
  • 13 CONSTRUCTIONAL REQUIREMENTS
  • 14 MECHANISM
  • 15 RESISTANCE TO AGEING, TO HARMFUL
  • 16 INSULATION RESISTANCE
  • 17 TEMPERATURE RISE
  • 18 MAKING AND BREAKING CAPACITY
  • 19 NORMAL OPERATION
  • 20 MECHANICAL STRENGTH
  • 21 RESISTANCE TO HEAT
  • 22 SCREWS, CURRENT-CARRYING PARTS
  • 23 CREEPAGE DISTANCES, CLEARANCES
  • 24 RESISTANCE OF INSULATING MATERIAL
  • 25 RESISTANCE TO RUSTING
  • 26 TESTS
  • 3 TERMS AND DEFINITIONS
  • 7 CLASSIFICATION
  • 5 GENERAL REMARKS ON TESTS

Test methods it refers to

  • IS 1401
  • IS 9000

Edition history (per the BIS registry)

  • IS 3854 : 2023 — current edition

Where this standard is used on NirmanDost

Listed by product makers

27 products in the NirmanDost catalogue name this standard on their spec sheets — Arteor Advance Classic Switch 10A - Matt White, Arteor Advance Classic Switch 16A - Matt White, Arteor Modular Wiring Devices Range. That is the maker’s own claim, copied as printed; we have not tested these products against the standard, and a spec sheet can cite the wrong code.

Materials market

Also cited in the Materials Market rate library and SKU sheets.

Find IS 3854 on the official BIS portal All IS codes used on NirmanDost

Pick up from here

Notes

  • Status and titles come from the official BIS published/withdrawn standards registry (standards.bis.gov.in exports, July 2026 snapshot). Editions change — verify on the BIS portal before contractual use.